0

combustion tests in lunar or Martian gravity. Every flight investigation in the catalogue ran in microgravity.

Source: official challenge brief, Flame in Freefall; PSI Data Repository search “combustion”

31.9%

highest oxygen of any solid-fuel test point

275 test points with a stated outcome

0 of 276

droplet tests with both CO2 and helium

NASA/TP-2015-216046, Table IX

39 of 60

n-heptane “extinctions” that kept burning

NASA/TP-2015-216046, Appendix B captions

Gap 1

Partial gravity

No repository dataset. The nearest real evidence is one suborbital flight and a few short ground tests.

Spread rate: simulated lunar gravity against normal gravity

One flight, preliminary slides. Lunar gravity came from spinning the capsule, so Coriolis force affects the flames.

  • Simulated lunar gravity
  • Normal gravity, same hardware

verified against the cited sourceSource: Ferkul et al., ASGSR 2025 presentation, slides 19, 33, 36 (NTRS 20250010653). A conference presentation, not peer reviewed, not a repository dataset. The PMMA values are printed as 0.15 and 0.40 cm/s. · open source

NO DATA

0

lunar- or Martian-gravity combustion datasets in the repository

Source: official challenge brief, Flame in Freefall

0.92mm/s

fabric flame-base spread in simulated lunar gravity, against 1.5 mm/s in normal gravity

Source: ASGSR 2025 presentation, slides 19, 33 (NTRS 20250010653)

2.3% O2

worst-case shift in flammability limit between normal and lunar gravity, five materials at 8.2 psia

Source: Urban et al., ICES-2025-392, Table 2 text (NTRS 20250002114)

Spread rate vs gravity is non-monotonic in the models and in low-conductivity-core wire tests, with a maximum and a minimum flammability O2 near lunar gravity; thin-cellulose KC-135 data at 0.2–0.4 atm are monotonic in g over 0.1–1 g. The peak location is material-, geometry- and pressure-dependent and is not yet fixed by a lunar-surface measurement — that is what FM2 is for.

Gap 2

Solid materials above the tested oxygen range

Each mark is one test point. The shaded band has no test; the dashed box is where future cabins are expected to sit.

  • sustained
  • quenched
  • blown off
  • no ignition

Source: 275 solid-fuel test points with a stated outcome: NASA/TM-20210011385 (BASS-II), PSI-99 table, Olson et al. 2023, ICES-2024-365, ICES-2025-156, NTRS 20240007628. Solid fuels only; droplet and gas tests are not on this chart. 243 of the 313 points have an assumed pressure: A pressure marked as assumed is not printed for that test. BASS-II tests outside the fabric table are taken as 1 atm (the memo states 1 atm for the fabric tests; the others ran in the same glovebox), and the Saffire VI Nomex sample is given its campaign's initial pressure. · open source

NO DATA

0

solid-material test points above 34% oxygen, at any pressure

Source: 275 solid-fuel test points

31.9%

highest oxygen with a recorded outcome: Saffire-VI Nomex, no ignition

Source: Niehaus et al., ICES-2025-156, Table 1 (NTRS 20250002675)

31.0%

highest oxygen with a sustained flame: Saffire-VI SIBAL-cotton at 54.1 kPa

Source: Urban et al., ICES-2024-365, Table 1

Gap 3

Carbon dioxide and helium together

Every FLEX test lies on one of the two axes. The two diluents were never combined.

  • Methanol
  • n-Heptane

Source: NASA/TP-2015-216046, Table IX. · open source

NO DATA

0

of 276 tests contain both gases

Source: NASA/TP-2015-216046, Table IX

123

tests with carbon dioxide

Source: NASA/TP-2015-216046, Table IX

51

tests with helium, at their own oxygen levels and pressures: its effect is unclear

Source: NASA/TP-2015-216046, Table IX

What you can't see · 1

Cool flames after the visible flame is gone

“Extinction” in the table means the visible flame. For n-heptane, the droplet often kept vaporising.

n-Heptane tests logged as Extinction (n = 60)

  • Cool-flame evidence39
  • No evidence8
  • Unclear6
  • Caption silent7

Source: NASA/TP-2015-216046, Appendix B figure captions: the authors' reading of continued vaporisation and a vapour cloud after the visible flame vanished. No methanol caption mentions a cool flame. · open source

39 of 60

kept vaporising after the flame disappeared. “No visible flame” is not “fire out”

Source: NASA/TP-2015-216046, Appendix B captions

What you can't see · 2

Smoke too fine for the detector

Geometric mean particle diameter by material, fresh and after 720 s, against the 500 nm mark.

  • Fresh smoke
  • After 720 s

verified against the cited sourceSource: Urban et al., SAME Final Report (NIST, 5 Mar 2010), Table 1 · read: full text · open source

The two flights used different hardware and diagnostics and their values differ by about a factor of two. They are kept as two tables and never averaged.

½ · ⅔

of Kapton and of Teflon smoke tests in which the station-type detector did not alarm

Source: Fire-detection white paper for the 2023-2032 Decadal Survey, p. 2 (summarising SAME results)

80nm

fresh Kapton smoke, against a 500 nm mark

Source: Urban et al., SAME Final Report (NIST, 5 Mar 2010), Table 1

981s

for a far-field detector to reach its alarm threshold in a vehicle-scale burn

Source: ICES-2024-365, p. 5 and Fig. 7

What you can't see · 3

Dim blue flames, and an oxygen figure that is not a cabin

Near its limit a flame shrinks and turns blue. And 85% O2 in the tables is a burner feed, never an ambient.

Near the limit, in the solid-fuel tests

the flame shrinks to a hemispherical blue flame and oscillates with increasing amplitude just before going out

verified against the cited sourceSource: NASA/TM-20210011385 §6.1.1 (report p. 64) · open source

Other gaps found while checking sources

A number that is quoted but could not be found, or a table that is not open.

  • A smoke-detection delay in microgravity compared with normal gravity, in seconds

    No published number. The SAME report says lags are longer and gives none; Saffire gives absolute microgravity times only.

    Source: SAME Final Report abstract; ICES-2024-365; ICES-2026-577

  • Cool-flame burning rates for n-heptane

    No open table. Hot and cool rates are published for n-decane and n-octane only; Table IX gives hot-flame rates.

    Source: NTRS 20140006750; NASA/TP-2015-216046

  • One-step cool-flame kinetic parameters fitted to FLEX (2012)

    Not openly available. A later six-step model is open and is cited instead.

    Source: Williams and Nayagam 2019 (open copy)

  • Numeric extinction or dilution limits for coflow and spherical gas flames

    Qualitative statements only in every open source read.

    Source: ACME overview, JASMAC-33 (NTRS 20210022542)

  • BASS-II extinction velocities for most rod and film tests

    Recorded as fan settings; the memo prints no conversion to cm/s, so 100 of 290 test points have no velocity.

    Source: NASA/TM-20210011385, Appendix A

  • Numbers that appear only in the 2019 BASS-II conference paper

    Not re-read: the repository blocks automated access. Marked as not verified wherever they appear.

    Source: ICES-2019-101

NO DATANothing on this page is filled in

Every gap above is shown as a gap. No value is interpolated, scaled for gravity, or carried from one kind of fuel to another.

Spacesuits are filled with 100% oxygen at 4.3 psi; the atmosphere used on the Moon will likely be 30% oxygen or more at 10.2 psi or less. Nothing in this data set speaks to the spacesuit condition. Source: Official challenge brief, Flame in Freefall.